Not taken — the garage was chosen. On 30 October 2026 John decided to stay in his garage with two machines. This page stays published for reference; the final layout is on Garage Print Lab.
Alternate location · 8 McLaren Suite E · revised for the doors

If he took 8 McLaren, Suite E

John read the first version of this page and wrote back one line: “The doors to the rest room and office are blocked.” He was right, and this is the revision. Both doors are now drawn with their swings, both are kept clear, and the question he actually asked — do four machines fit, with room for a metal printer — still answers yes.

The garage plan has not changed. This is still the “what if he took this place instead” version, meant to be read against it.

What was wrong

The first version never drew the two interior doors. They are on the brochure plan — two small quarter-circle arcs — and because I had not transcribed them, I parked the wash bench and the waste drums exactly where they open.

Measured, not guessed. The waste drums landed inside the office door’s swing, at 15.49, 25.13 ft. The ultrasonic tank and the drums together covered the approach to the restroom door. Running the old layout back through the clearance check used on this page reports three separate blockages; the revised layout reports none.

The printers were never the problem. They stop at 17.6 ft from the front wall and the restroom wall does not start until 20.4 ft. So the machines did not move at all. The post-processing did — the sink to the restroom’s outside corner, the tank into the middle band, the drums up beside the sink.

The short answer

Yes — four still fit, with both doors fully clear. Four service envelopes take 330.8 sq ft of about 782.2 sq ft of warehouse floor, two across and two deep. Everything else John listed has a place, a reserved bay is held for the metal printer, and 351.6 sq ft — 45% of the warehouse — is still floor you can walk on.

And no — that is not the only way this works. John asked. Below the revised plan there is now a second arrangement, Layout B, that pushes every machine and every wash station out to the walls and keeps one straight 6.5 ft walkway down the centre. Four machines fit in that one too, both doors stay clear, and there is 383 sq ft of walkable floor against 340 here. It costs a longer plumbing run and the reserved metal-printer bay. Pick on how the room should feel; the numbers for both are below.

Layout A — the revised plan

24.1 ft overall 5.3 9.4 9.4 8.8 8.8 41.65 ft 3.2 4.4 ft 5.0 ft 6.1 ft GL 6.4 ft ~2.4 ft ~2.5 ft 1 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 8 McLaren, Suite E · Irvine Business Center · REVISED ±972 SF published · everything else scaled off the brochure plan 1 Mimaki 3DUJ-553 × 4 — 9.4 × 8.8 ft each, including Mimaki's service clearance; body 7.42 × 4.92 ft shown solid. Two across × two deep, 331 SF of 782 SF. 2 Utility sink + drainboard 3.0 × 2.5 ft, set at the restroom's outside corner for the shortest tie-in to existing supply and waste. 3 Three-tank ultrasonic support removal, 5.5 × 3.0 ft — takes a 20×20×12 in part. 4 Wastewater drums on a 2-drum spill pallet, 4.25 × 2.17 ft. SW-100 must NOT go to sewer — these are collected and hauled. 5 Workbench 1.8 × 8.0 ft on the west wall. 6 Shelving 1.2 × 10.0 ft — kept shallow to hold the crate route open. 7 METAL PRINTER — bay reserved, 4.85 × 8.0 ft, dashed. No model named yet. 8 Proposed electrical sub-panel. The existing service position is not on the brochure. 9 Ground-level door, scales to 6.4 ft. MEASURE IT (see note). 10 OFFICE DOOR — 2.4 ft leaf, hinged on the east jamb, swings NORTH into the warehouse. Its full quarter-circle swing is drawn and kept clear. 11 RESTROOM DOOR — 2.5 ft leaf, hinged on the south jamb, swings EAST into the restroom, so its arc is inside that room; the approach side is kept clear. 12 DOOR CLEAR ZONE, hatched — 4.4 × 5.0 ft. Nothing is placed in it. 13 Restroom, existing — 50.6 SF. 14 Reception / office, existing — 140 SF. 15 Reception's own exterior entry door, existing. WHAT CHANGED, AND WHY. John is right about the first version: the wash bench and the waste drums sat across both doorways. The drums fell inside the office door's swing at 15.5, 25.1 ft. The four printers were never the problem — they stop at 17.6 ft and the restroom wall starts at 20.4 ft. So the machines did not move; the post-processing did. FOUR STILL FIT with both doors fully clear. THE TWO DOORS CROWD EACH OTHER — that is the building, not this layout. Their jambs are 0.55 ft apart, so the office door standing open reaches across the approach to the restroom. Both work; both at once is awkward. Re-hanging the office door on the opposite jamb would swing it away and cost little — a landlord question, not something assumed here. Orange hatch is kept-clear floor: 5.0 ft deep at the office door (front approach, pull side) and 4.0 ft at the restroom door (push side). That is the generous reading; the building department decides what actually applies. CRATE ROUTE. The crate's narrow face is 5.9 ft. The ground-level door scales to 6.4 ft and the permanent corridor past the shelving and the reserved bay is 6.1 ft — 2 in. of margin on a drawing that carries no door dimension. Measure the clear width and height on site before ordering anything. INSTALL ORDER. Set the EAST column of machines first, then the west: the main aisle finishes at 3.2 ft, narrower than the crate. Bench, shelving, drums and the reserved bay are all fit-out items that follow the machines in. Ventilation is NOT decided on this plan and no extraction is drawn.
Layout A — machines grouped, post-processing across the middle. Orange hatch is floor kept clear for the two doors; the quarter-circle arcs are the door swings themselves. Dimensions in feet. On a narrow screen the plan scrolls sideways rather than shrinking.

Layout B — everything against the walls

Same suite, same four machines, same two doors. The difference is where things stand. Layout A groups the printers and runs the post-processing across the middle of the floor. Layout B puts the four machines in two columns hard against the side walls, turns the wash line into one continuous run along the west wall in work order — rinse, ultrasonic, waste — and leaves the centre of the room as a single straight walkway with nothing standing in it.

24.1 ft overall 8.8 6.5 8.8 9.4 9.4 41.65 ft 6.5 ft CLEAR WALKWAY 9.1 ft wash line 13.2 ft 4.4 ft 5.0 ft GL 6.4 ft ~2.4 ft ~2.5 ft 1 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LAYOUT B · 8 McLaren Suite E · perimeter-first ±972 SF published · everything else scaled off the brochure plan 1 Mimaki 3DUJ-553 × 4 — 9.4 × 8.8 ft each including Mimaki's service clearance, here turned 90° so each column runs along its wall; body 7.42 × 4.92 ft shown solid. Two columns of two, 331 SF of 782 SF. 2 Utility sink + drainboard 3.0 × 2.5 ft — first station of the wash line. 3 Three-tank ultrasonic support removal, 5.5 × 3.0 ft — takes a 20×20×12 in part. 4 Wastewater drums on a 2-drum spill pallet, 4.25 × 2.17 ft. SW-100 must NOT go to sewer — collected and hauled. 5 Workbench 1.8 × 8.0 ft, continuing the same wall line. 6 Shelving 1.2 × 10.0 ft on the opposite wall — shallow, to hold the crate route open. 7 Electrical sub-panel, proposed — moved to the head of the walkway so all four machines are a short feeder away. Existing service position is not on the brochure. 8 Ground-level door, scales to 6.4 ft. MEASURE IT (see note). 9 OFFICE DOOR — 2.4 ft leaf, hinged on the east jamb, swings NORTH into the warehouse. Its full quarter-circle swing is drawn and kept clear. 10 RESTROOM DOOR — 2.5 ft leaf, hinged on the south jamb, swings EAST into the restroom; the approach side is kept clear. 11 DOOR CLEAR ZONE, hatched — 4.4 × 5.0 ft. Nothing is placed in it. 12 Restroom, existing — 50.6 SF. 13 Reception / office, existing — 140 SF. 14 Reception's own exterior entry door, existing. 15 THE CENTRAL WALKWAY — 6.5 ft clear and straight for its whole 18.2 ft run, with nothing standing in it. This is what the layout is FOR. WHY A SECOND LAYOUT. John asked whether the revised plan was the only way this works. It is not. Layout A groups the machines and runs the post-processing across the middle of the floor; Layout B pushes everything to the walls and keeps one straight walkway down the centre. Both put four machines in the suite and both keep the two doors fully clear. The difference is how the room FEELS to stand in, which is a preference, not a calculation. WHAT LAYOUT B BUYS. Walkable floor measured by flood fill from the ground-level door: 383 SF, against 340 SF for Layout A. The narrowest point on the route from the office door to the exit widens from 3.6 ft to 4.6 ft, and the walk up the centre from 3.2 ft to 4.4 ft. The wash line becomes one continuous run in work order — rinse, ultrasonic, waste — instead of three islands. WHAT IT COSTS, STATED PLAINLY. Three things. The wash line moves to the west wall, roughly 14 ft from the restroom, so the supply and waste tie-in is a real plumbing run rather than a short one — this is the main tradeoff and it is a cost question for the landlord. The reserved metal-printer bay does NOT survive: region C is 12.49 ft wide and bench, shelving, a 4.85 ft bay and a 5.9 ft crate route need 13.75 ft. And six service-envelope edges now sit flush to a wall against four in Layout A, so more of each machine's clearance is taken on the sides you can still reach. WHY THE WASH LINE IS NOT AGAINST THE RESTROOM WALL, WHICH WOULD HAVE BEEN THE SHORT PLUMBING RUN. It was drawn there first. The strip north of the restroom is 2.83 ft deep and the sink is 2.5 ft, which leaves 0.33 ft to stand in at the face you actually use. A station you cannot stand at is not a station, so it moved. THE TWO DOORS CROWD EACH OTHER — that is the building, not either layout. Their jambs are 0.55 ft apart, so the office door standing open reaches across the approach to the restroom. Re-hanging it on the opposite jamb would swing it away and cost little — a landlord question, not something assumed here. CRATE ROUTE. The crate's narrow face is 5.9 ft. The ground-level door scales to 6.4 ft, the region C run past the shelving is 9.1 ft, and the central walkway is 6.5 ft — so unlike Layout A the crate fits the finished walkway with 0.6 ft to spare and the install order is not forced. Measure the door's clear width and height on site before ordering anything. Ventilation is NOT decided on this plan and no extraction is drawn.
Layout B — perimeter-first. The dashed band down the centre is the walkway, dimensioned where it is narrowest. Dimensions in feet. On a narrow screen the plan scrolls sideways rather than shrinking.

The two side by side

 Layout ALayout B
Machines that fit44
Clearance check at both doors0 blockages0 blockages
Walkable floor, flood-filled from the ground-level door 340 sq ft383 sq ft
Straight central walkway3.2 ft aisle 6.5 ft, clear for its whole 18.2 ft run
Narrowest point, office door to exit3.6 ft4.6 ft
Narrowest point, up the centre to exit3.2 ft4.4 ft
Wash linethree islands in the middle band one continuous run on the wall
Plumbing tie-in to the restroomshort — at its outside corner about 14 ft across the floor
Reserved metal-printer bayyes, 4.85 × 8.0 ft no — see below
Service-envelope edges flush to a wall46
Crate fits the finished walkwayno — install order is forced yes, 0.6 ft to spare

What Layout B gives up

Three things, and none of them is hidden in the drawing. The plumbing run. Moving the wash line to the west wall puts the sink about 14 ft from the restroom, so supply and waste become a real run across the slab rather than a tie-in at the corner. That is the main cost and it is a question for the landlord, not something this plan can settle. The metal-printer bay. Region C is 12.49 ft wide; the workbench, the shelving, a 4.85 ft bay and a 5.9 ft crate route need 13.75 ft. It does not fit, so Layout B does not pretend to hold it. Clearance against walls. Six of the service envelopes' edges now sit flush to a wall, against four in Layout A — more of each machine's clearance is taken on the sides you can still reach.

One thing I tried first and threw away

The obvious place for the wash line is against the restroom wall, where the plumbing already is. It was drawn there first. The strip north of the restroom is 2.83 ft deep and the sink is 2.5 ft, which leaves 0.33 ft to stand in at the face you would actually use. A station nobody can stand at is not a station, so it moved to the west wall and took the plumbing run with it. That is why Layout B costs what it costs.

Ventilation is still open on both layouts. Neither drawing shows extraction, and nothing here decides it.

The two doors, measured

Both openings were measured as gaps in the wall runs on the brochure plan. Which jamb each door hangs on, and which way it swings, came from testing the four possible arrangements against the drawn arc — not from reading the picture by eye.

 Office / reception doorRestroom door
In which wallreception north, y = 26.92 ft restroom west, x = 16.30 ft
Opening (gap in the wall)13.38 – 15.75 ft → 2.37 ft 24.30 – 26.51 ft → 2.21 ft
Leaf, from the arc2.41 ft2.46 ft
Hinged oneast jambsouth jamb
Swingsnorth, into the warehouse east, into the restroom
Kept clear herewhole swing + 5.0 ft front approach 4.0 ft approach, warehouse side
In the first version drums inside the swing at 15.49, 25.13 ft tank and drums across the approach

The two doors crowd each other, and that is the building, not the layout. Their jambs are 0.55 ft apart. The office door standing fully open reaches across the approach to the restroom door. Both work; both at once is awkward, and no arrangement of equipment fixes it. Re‑hanging the office door on the opposite jamb would swing it away from the restroom and cost very little — but that is a change to the premises and a question for the landlord, so it is offered here, not assumed.

The clear zones drawn are the generous reading: 5.0 ft deep on the pull side of the office door and 4.0 ft on the push side of the restroom door. What actually applies to a suite this size is the building department’s call, not mine.

Key elements, dimensioned

#ElementFootprint, ftAreaWhy it sits there
1Mimaki 3DUJ-553 × 49.4 × 8.8 each330.8 sq ftEnvelope includes Mimaki’s service clearance; body is 7.42 × 4.92 ft. Two across, two deep, clear of both doors.
2Utility sink + drainboard3.0 × 2.57.5 sq ftSet against the restroom’s outside corner — the shortest possible tie-in to supply and waste, and clear of the door below it.
3Three-tank ultrasonic5.5 × 3.016.5 sq ftTakes the 20×20×12 in part John quoted. Sits on the north edge of the middle band, out of both door zones.
4Wastewater drums, 2-drum spill pallet4.25 × 2.179.2 sq ftBeside the sink, so the wash line is short. SW-100 cannot go to sewer — these are collected and hauled.
5Workbench1.8 × 8.014.4 sq ftWest wall. Kept shallow on purpose: it is what holds the main aisle at 3.2 ft.
6Shelving / material storage1.2 × 10.012.0 sq ftLower leg, west wall. Shallow so the crate route past it stays open.
7Metal printer bay, RESERVED4.85 × 8.038.8 sq ftHeld empty. No model has been named, so this is floor set aside, not a design.
8Electrical sub-panel0.6 × 2.3—Position is proposed. The existing service location is not shown on the brochure.
 Everything above— 430.6 sq ft Of 782.2 sq ft of warehouse. Leaves 351.6 sq ft to move in.

Power

The brochure lists 100 Amps, 120–208V, 3 Phase under the property highlights, and adds its own (verify). At 100 A and 208 V three-phase that is about 36,027 VA.

LoadQtyWatts eachWattsOf service
Mimaki 3DUJ-55341,630 6,52018.1%
Ultrasonic support removal, heated1 ~1,5001,500—
Bench, lighting, small tools— ~1,0001,000—
Printing and finishing   9,020 25.0%
Extraction — only if the filter option is taken 2~370740 —
With extraction   9,760 27.1%

Headroom is not the constraint here. The figures for anything other than the printers are estimates and should be replaced with the nameplate of whatever is actually bought — and the service itself still needs the verification the brochure asks for.

Air — still open on this plan

No decision is made here and no extraction is drawn. The garage page shows one option; whether this suite gets filtration units beside the machines, a ducted extract, or something that uses the 14 ft height, is still open. It changes the power line above by about 740 W and nothing else on this layout — the equipment positions do not depend on it.

Post-processing and waste

This part of the plan comes from John’s own list, not from guesswork:

Getting a crate in, and in what order

A crated 3DUJ-553 is 5.9 ft across its narrow face.

Measure the ground-level door before ordering anything. 6.4 ft against a 5.9 ft crate is six inches — and that 6.4 is scaled off a leasing brochure that carries no door dimension at all. A door symbol on a brochure is drawn to look right, not to be measured. Clear width and clear height, on site, with a tape.

What is published, and what I scaled

Only a handful of numbers here come from the landlord. Everything else is measured off the drawing, and is labelled as such.

Published by the brochureScaled off the drawing by me
±972 SF (Suite E) every wall, room and door position
14 ft minimum clear height 24.1 × 41.65 ft overall
ground-level doors ground-level door 6.4 ft wide
100 A, 120–208 V, 3 phase (verify) both interior door openings and swings

The one check worth reporting. The scale was set so the suite outline closes on the published area. Drawn from the measured walls it comes out at 972.8 sq ft against a published ±972 — warehouse 782.2, restroom 50.6, reception 140.0. That agreement is what makes the rest of these numbers worth quoting. It does not make the door symbol trustworthy.

The three property figures above are listed for the whole of Irvine Business Center — six suites across several buildings — not for Suite E specifically. The brochure also states plainly that nothing in it is an offer or a warranty.

The garage and this suite, side by side

 The garage8 McLaren Suite E
Machines it takes24, + a reserved bay
Clear heightdomestic14 ft published
Getting a crate intight, and his own driveway ground-level door, 6.4 ft scaled
Plumbing for the wash linenew run to the garage existing restroom, a few feet away
Water heater / furnace in the roomyes — backdraft matters no
Costfit-out onlyrent, ongoing

The honest difference is not floor area, it is that the garage is his and this is not.

Before signing anything

Related

← Kindro