Planning notes for a full-color 3D printing shop built around a Mimaki 3DUJ-553 class printer, three design workstations, receiving, finishing, storage, and the site checks that matter before signing.
This candidate uses the existing small-industrial plan: a direct receiving zone, print zone, finishing bench, and design studio sized for three operators.
Tap the plan for full size, or download the PNG.
Finished office suite is already built out: reception/showroom, two glass-front offices, kitchenette, and ADA restroom. The production hall has white walls, sealed concrete, and an insulated ceiling. The keyed composite is re-oriented so the glass storefront reads as the street-facing end wall and the window band reads as the hall exterior side wall.
All items below are ASSUMED planning requirements. VERIFY against the actual printer spec sheet and a site walk before signing or moving equipment.
Crate approximately 8' x 5'-6", approximately 1,300 lb, pallet-jack route, no steps. Needs approximately 6'+ clear opening. Suite F: roll-up door = easy. Warner: glass storefront entry - measure clear width; worst case temporary storefront-glass-panel removal (approximately $500-$1,500 by a glazier) is routine but must be pre-approved by landlord.
UV-cure inkjet (Mimaki 3DUJ-553 class) is low-VOC; assume dedicated exhaust over the wash/cure/finishing bench plus 4-6 air changes/hour in the print area; no spray booth; keep HVAC airflow off the print bed.
Coastal Orange County: printer wants approximately 68-77 deg F and 35-65% RH non-condensing. Region is mild - assume a 2-3 ton mini-split holds an insulated hall; heating rarely runs but keep 65 deg F+ on winter nights for media stability.
Assume printer needs a dedicated 200-240V single-phase 15-20A circuit (approximately 2 kW class - VERIFY spec sheet; three-phase NOT expected for this machine class), plus two dedicated 120V/20A circuits for wash/cure/compressor, plus normal office loads. A standard 100A panel should carry it - confirm panel capacity and spare breaker slots on the walk.
Approximately 1,100 lb machine on slab-on-grade is fine; no reinforcement assumed.
Business internet, fire extinguishers rated for electrical, and insurance rider for the machine.